Now for the moment we’ve all been waiting for- creating some ladder logic. Open the RSLogix Micro software with the START > All Programs > Rockwell Software > RSLogix Micro English > RSLogix Micro English shortcut. Create a brand new project by pulling down the File menu and selecting New. Every project must start with a designated processor.Â

Rslogix 500 emulator tutorial drivers#

Ok, that’s ready to go. Close the Configure Drivers dialog box and close RSLinx. Actually RSLinx is now running in the background and you’ll probably see its little icon in the system tray.

Rslogix 500 emulator tutorial driver#

Your driver should now be running and look like the picture below.

  • Leave the configuration options as Station Number 00 and click OK.
  • rslogix 500 emulator tutorial rslogix 500 emulator tutorial

  • You can give the driver a name but I just leave it at the default of EMU500-1.Â.
  • Under the Available Drivers Types select the “SLC 500 (DH485) Emulator driver” and click the Add New… button.Â.
  • Under the Communications menu select Configure Drivers.
  • rslogix 500 emulator tutorial

    Let’s start by running the RSLinx software under the START > All Programs > Rockwell Software > RSLinx > RSLinx Classic shortcut. Follow these steps to set it up: RSLinx is the software RSLogix will use to communicate with your PLC or in our case to the emulator.

    Rslogix 500 emulator tutorial install#

    Once you’ve downloaded the software and extracted it then install RSLogix Micro followed by the RSLinx Classic Lite software. Next, install the RSLogix Emulate 500 software.

    Rslogix 500 emulator tutorial update#

    Note for Windows XP users: The bundled version of RSLinx only installs on Windows Pro and is not supported on Windows XP Home versions. To get around this I downloaded an older version of RSLinx Lite 2.50 from the Allen Bradley software update page If you do not have a MicroLogix 1000 or 1100 to play with then download the RSLogix Emulate 500 software. You’ll be able to use this to simulate a real PLC. The RSLogix Micro Starter Lite software is only available as a download at If you are starting from scratch and do not have the RSLinx software then download the kit bundled with RSLinx Classic Lite. FYI, I find it a bit confusing but they also sell software called RSLogix Micro Starter which supports the full MicroLogix range.

    Rslogix 500 emulator tutorial for free#

    RSLinx Classic must start as an application RSLinx Classic will not start as a service.įor RSLinx Classic to function as an OPC server, you must be logged on and RSLinx Classic must be running as an application.One of my most common questions is, “Where can I get a free download of RSLogix 500?” For any serious development with SLC500 or MicroLogix there is no free option but there is a nice free option if you only want to learn and/or program a MicroLogix 1000 or 1100. Programming a MicroLogix is very very similar to programming a SLC500 or in that case a PLC5 too.ÂĪllen Bradley offers as a free download a software package called RSLogix Micro Starter Lite which is essentially the same programming environment as RSLogix 500. On top of that, they also offer RSLogix Emulate for free so that you don’t even need a PLC to run and test your ladder logic. Keep reading and I’ll show you how to get the software and set it up. Keep the following in mind when using RSLinx Classic v2.54.00 (CPR 9 Service Release 1) with Microsoft Windows Vista Business (Service Pack 1) or Microsoft Windows Vista Home Basic (Service Pack 1): RE: RSLinx+RSLogix+RSLogix Emulate500 and Vista el124 (Electrical)Īre you running Vista? If so see release notes here After selecting the driver you can choose the communications method you are trying to accomplish from the buttons on the right hand of the window: ONLINE, UPLOAD, DOWNLOAD: Select the processor that you wish to communicate with. Assign the Emulator driver a STATION NUMBER and STATION NAME:ġ3. The default name (EMU500-1) is usual recommendation.ĩ. Expand Available Driver Types drop down box and select SLC 500 (DH485) Emulator driver and hit ADD NEWĨ. A Debug File # if used can also be specified.Ħ.

    rslogix 500 emulator tutorial

    Select the file you want to run in RSEmulate and press the OPEN buttonĤ. Use the FILE pull down menu and select OPENģ.